Filcom

Controller created precisely for filter backflush 2, 4, 6 stations (on the 4 and 6 stations it is possible to control also the pressure sustaining valve)

Set interval between complete backflush cycles:

  • in minutes (from 10 to 90 minutes, 10 by 10 minutes)
  • in hours (from 2 to 24, 1 by 1 hours)
  • it is possible to choose to have this interval set by the differential pressure sensor

Set the backflush time per station:

  • from 0 to 90 seconds (5 by 5 seconds)
  • from 2 to 10 minutes (1 by 1 minutes)
  • Set the delay between 2 stations: from 0 to 90 seconds (5 by 5 seconds)

It is possible to set the delay for the reaction of the differential pressure sensor: from 5 to 90 seconds

Permanente memory
It is possible to set the duration of the impulse to the latching solenoids from 10 to 99 ms
Number of the cycles execute after last reset is showed on display

1 led (Alarm) signal if a short cut has happened or if the differential pressure sensor has been actived

Two digit display

Each one of 6 led (related to the 6 stations) flasheswhen the station is working